1、Introduction(LYXW9000F Multifunction Three-phase Phase Voltammeter)
LYXW9000F Multifunction Three-phase Phase
Voltammeter, is a multifunction meter with touch screen, which can measure
voltage amplitude, current amplitude, voltage phase, current phase, frequency,
power, active power, reactive power, harmonics, and can display the vector
illustration of three-phase voltage and three-phase current in real time. In
addition, it can also judge the three-phase phase sequence, inductive and
capacitive circuits, test the secondary circuit, check whether the wiring of
the watt-hour meter is correct or not, inspect and repair the line equipment,
etc. This meter is simple to operate, easy to use, fast, stable and reliable in
measurement. Widely used in electric power, petrochemical, metallurgy, railway,
meteorological and other department.
LYXW9000F Multifunction Three-phase Phase
Voltammeter consists of the host, clamp current sensor, and voltage test line.
the meter equip with 5-inch touch color screen, uses the large-capacity
rechargeable lithium battery, which can automatic measurement, simple and fast
operation, accurate and reliable, has the
functions such as data storage, data query, automatic shutdown, USB data
upload and export, etc. Since adopt the dedicated metering chip, the meter has
very high-precision electrical parameter measurement, can display the changes
of the measured parameters in real time, and has the function of saving data
with one key.
This meter has the following functions and
features:
1.High measurement accuracy, voltage and
current accuracy up to 0.3; phase accuracy up to ±0.3°;
2. Measurement mode: Single-phase,
two-phase, three-phase, three-phase four-wire system and three-phase three-wire
system;
3. Analyze and measure harmonics within the
21st order of voltage and current;
4.The measurement personnel only need to
connect the wires, the instrument will automatically measure and update the
data in real time, which is convenient for on-site analysis;
5.The instrument adopts complete isolation
technology to avoid safety accidents;
6.Touch color screen, easy and fast
operation.
2、Electrical Symbols(LYXW9000F Multifunction Three-phase Phase Voltammeter)
|
Extremely dangerous! The operator must
strictly follow the safety rules, otherwise there would be danger of electric
shock, causing personal injury or injury accident.
|

|
Dangerous!The operator must strictly follow the safety rules, otherwise
there would be danger of electric shock, causing personal injury or injury
accident.
|

|
Warning!Operators must strictly follow safety rules , otherwise personal
injury or equipment damage may occur
|

|
AC
|

|
DC
|

|
Double insulation
|
3、Technical Specification(LYXW9000F Multifunction Three-phase Phase Voltammeter)
3.1.Base Conditions and
Working Conditions
|
Influence Quantity
|
Base Condition
|
Working Conditions
|
Remark
|
|
Environment Temperature
|
23℃±1℃
|
-10℃~40℃
|
|
|
Environment Humidity
|
40%~60%
|
<80%
|
|
|
Signal Waveform
|
sine wave
|
sine wave
|
β=0.01
|
|
Signal Frequency
|
50Hz±1Hz
|
45Hz~65Hz
|
|
|
Meter Working Voltage
|
7.4V±0.2V
|
7.4V±1V
|
|
|
The current amplitude when measure the
phase frequency and phase sequence
|
4A±10mA
|
1mA~20A
|
----
|
|
The voltage amplitude when measure the
phase frequency and phase sequence
|
100V±10V
|
2V~600V
|
----
|
|
The current amplitude when measure the
power and power factor
|
4A±10mA
|
1mA~20A
|
----
|
|
The voltage amplitude when measure the
power and power factor
|
100V±10V
|
2V~700V
|
----
|
|
External Electric Magnetic Field
|
To be avoided
|
|
The Tested Wire Position
|
Measured wire at approximately the
geometric center of the clamp
|
3.2.General
Specification
|
Power Supply
|
DC 7.4V 5200mAH rechargeable battery
|
|
Function select
|
Select on trouch screen
|
|
Display Mode
|
5 inch trouch colorful screen
|
|
LCD Size
|
108mmX65mm
|
|
Meter Size
|
210mmX129mmX68mm
|
|
Weight
|
Host:870g; Total weight: 2kg(with
accessores&pcaking)
|
|
Test Lines
|
1pcs each voltage test line of yellow,
green,red, black
|
|
Clamp Current Sensor
|
CT size: φ8mm, 3pcs
|
|
Data Store
|
1000 groups
|
|
Data Query
|
Yes
|
|
Data Upload
|
USB interface, the test record data
upload to computer, and can export with EXCEL format file
|
|
Battery Voltage
|
With battery power state indicator,
battery voltage lower than 10% will remind to charge in time
|
|
Automatic Shutdown
|
15minutes without any operation after
power up, will automatic shutdown, and remind beofore shutdown
|
|
Working Time
|
Continue working about 12 hours with full
charge battery power
|
|
Power Consumption
|
Working(backlight is 50): 320mA
|
|
Working Condition
|
-20℃~50℃; Relative humidity: 0~95%HR non-condensing
|
|
Storage Condiction
|
-30℃~60℃;
Relative humidity: 0~75%HR
|
3.3.Intrinsic Error And
Performance Index Under Base Conditions
|
Category
|
Measure Range
|
Accuracy
|
Resolution
|
|
Voltage
|
2V~100V
|
±0.3%Fs
|
0.0001V
|
|
100V~700V
|
0.0001V
|
|
Current
|
0.001A~1A
|
±(0.3%Fs ±0.2%rdg)
|
0.0001A
|
|
1A~10A
|
0.0001A
|
|
10A~20A
|
0.0001A
|
|
Harmonic
|
2~21 orders
|
--
|
--
|
|
Phase
|
0°~360°
|
±1°
|
0.1°
|
|
Frequency
|
45Hz~65Hz
|
±0.03Hz
|
0.0001Hz
|
|
Power(include active pwer, reactive
power, apparent power)
|
0.002W~1000W
|
±0.3%Fs
|
0.0001W
|
|
1000W~10000W
|
0.0001W
|
|
10000W~14000W
|
0.0001W
|
|
Power Factor
|
-1.000~1.000
|
±0.03
|
0.001
|
Note: The measurement error under working
conditions is not more than twice the base condition, and the phase error: 20mA~20A is ±2°; below 20mA ±6°.
4、Meter Structure(LYXW9000F Multifunction Three-phase Phase Voltammeter)

|
1.Host
|
2.Touch screen
|
|
3.Data hold key
|
4.Power key
|
|
5. Voltage test line
interface(U1,U2,U3,Un)
|
6.Current test line
interface(I1,I2,U3,I3)
|
|
7.Charge interface
|
8.Charge indicator
|
|
9.USB interface
|
10.Current test lines
|
|
11. Voltage test lines
|
12. Usb cable
|
|
13.Charger
|
|
5、Measurement Wiring
Connection(LYXW9000F Multifunction Three-phase Phase Voltammeter)
5.1.Voltage Test Line
Wiring
Connect the voltage test lines(yellow,
green, red, black) to the U1 (yellow), U2 (green), U3 (red), and Un (black)
terminals of the host, and ensure that there is no looseness, as shown in
Figure 1:
5.2. Y Type Wiring
Connection
Clamp the Un voltage line terminal (line
color is black) to the meausred voltage signal netural line, clamp the U1, U2,
U3 voltage lines terminal (line color is yellow, green, red) to three-phase phase line A, B, C; If only need
to measure single phase voltage, clamp the Un voltage line terminal to the
neutral line, and clamp the U1 voltage line terminal to the tested phase line
(the meter can use any measurement interface to measure a certain phase
voltage); if measure two-phase voltage , clamp the Un voltage line terminal to
the neutral line, and clamp the U1 and U2 terminals to the tested phase.
The red dot on the clamp current sensor
marks the positive direction of current flow. Clamp I1, I2, and I3 current
sensor (the round lable on the current sensor as yellow, green, and red) to the
three-phase phase lines of A, B, and C. If only need to measure one channel
current, clamp the I1 clamp current sensor to the tested current line (the
meter can measure a certain phase current at will); if measure two channels
current, clamp the I1 and I2 clamp current sensors to the tested current line. The wiring
diagram is shown in Figure 2:
5.3.Triangle Type Wiring
Connection
5.3.1. Three clamp wiring connection method
Clamp U1, U2, and U3 voltage line terminals
(lines colors are yellow, green, and red) to the three-phase phase lines A, B, and C. The
arrow on the side of the clamp current sensor
indicates the current flow direction, and Un is not connected. Clamp I1,
I2, and I3 clamp current sensor (the round label on the sensors are yellow,
green, and red) to the three-phase phase lines A, B, and C. The wiring diagram
is shown in the figure3:

5.3.2. Tow clamp wiring connection method
Clamp U1,
U2, and U3 voltage line terminals (lines colors are yellow, green, and red) to
the three-phase phase lines A, B, and C.
The arrow on the side of the clamp current sensor indicates the current flow direction, and Un
terminal is not connected. Clamp I1, and I3 clamp current sensor (the round
label on the sensors are yellow and red) to the three-phase phase lines A and
C. The wiring diagram is shown in the figure4:
6、Operation
6.1.Power On/Off & Battery Power
6.1.1.Power on. The meter is power off state, press the power key to
start on, and enters the start-up interface, as shown in Figure 5. After the
initialization is completed (about 5 seconds), enter to the main menu
interface.After the meter power on and enter the main menu interface, just
click the corresponding function icon to enter the corresponding function
option (the calibration function belongs to our calibration personnel and is
not available to users). As shown in Figure 6
6.1.2.
Power off. When the meter is on the state of power on, press the power button
to power off. When the meter power up and without any operation for 15 minutes,
a page as shown in Figure 7 will pop up, prompting that the meter will be shut
down, click stop key, and the normal operation will resume.
6.1.3. Battery power. In the power-on
state, the percentage of battery power and icons will be displayed in the upper
right corner, and different colors have different colors, a total of 5 colors
are displayed, red
, yellow
, light green
, green
, dark green
.
6.2. Meter Interface
Operation
6.2.1. After entering to the test interface shown in Figure 9 and Figure
10, the meter will automatically measure the data and display the test data
every 0.3 seconds. If need to measure the single phase, only need to connect
the wiring of the measured phase, and do not connect the other phases,
otherwise the accuracy will be affected. If want to save the data, just click
the save key, and the buzzer will sound once when saving the data. Click the Harmonic
Analysis key to enter the harmonic analysis interface (as shown in Figure 11
below), and click U1 key to display the 2nd ~ 21st harmonic content and
histogram of the voltage U1, corresponding to the present harmonic analysis
below "U1", the vertical axis of the histogram on the left will also
display "U1 Histogram". Similarly, click U2, U3, I1, I2 or I3 will
display the corresponding data, and only one parameter data can be viewed at
the same time (U1, U2, U3, I1, I2 or I3) . click the BACK key return to voltage
drop test interface. Click the Waveform key to enter the waveform display
interface (as shown in Figure 12 below), and the two cycles waveforms of the
three channel voltages and three channel currents can be displayed on the same
screen. Click the U1 button to display the yellow waveform of U1, click the U2
button to display the green waveform of U2, click the U3 button to display the
red waveform of U3, click the I1 button to display the orange waveform of I1,
click the I2 button to display the dark green waveform of I2, click The I3
button displays the purple waveform of I3, and the waveform will disappear when
the button is clicked again, and the vertical coordinate can be zoom-in by
clicking the corresponding zoom-in button to make the waveform amplitude
larger, otherwise, the zoom-out button can make the waveform amplitude smaller.
Exit the page (click the HOME key or the left arrow under the page) to stop the
test.
Note: When the wiring connection type is
three-phase three-wire, the test interface will be different. Only the voltage,
current, voltage phase, current phase, frequency, total power factor, and total
active power in ttotal reactive power and total apparent power of the
three-phase three-wire will be measured during three-phase three-wire
operation. Waveforms can only analyze
the shape, not the phase relationship between them.
6.2.2. Harmonic distortion rate (also known as distortion rate) is the
ratio of the root-mean-square value of the harmonic content to the
root-mean-square value of the fundamental component in a periodic AC quantity.
The harmonic content rate is the ratio of the effective value of a multiple
harmonics content to the effective value of the fundamental component in the
periodic AC quantity.
6.2.3.Check the record operation, the interface is shown as Figure 13.
Just click the right arrow key on the test interface to enter the three-phase
history record interface, and the test date and serial number will be
displayed. Click the line where the serial number is located to enter the
three-phase test record interface, as shown in Figure 14, showing the details
of measurement data.Click the left arrow key on the detail interface to return
to the previous page, and then click the left arrow key to return to the test
interface. During operation, if find that there are too many data, can use the
clear button on the record interface to clear all the data. If the record need
to be saved permanently, it can be exported to an EXCEL form through the USB
connection to the host computer. Click the waveform display and harmonic
analysis to view the waveform and harmonic records, as shown in Figure 15 and
Figure 16.
6.3. Setting Interface
Operation
Enter the setting interface, can set the
time, wiring type, and backlight brightness. As shown in Figure 17. when exit
this interface, the meter will automatically save the parameters set by the
user.
6.3.1. Time set
The time setting can be modified by sliding
up and down the screen. After the modification, click Confirm to modify it
successfully.
6.3.2. Wiring type set
There are three types of wiring types:
three-phase four-wire, three-phase three-wire two-clamp method and three-phase
three-clamp method.
Note: When the wiring type is selected as
three-phase four-wire, the 1, 2, and 3 of all test interfaces are represented
as U1, U2, and U3 respectively; when the wiring type is selected as three-phase
three-wire, the 1, 2, and 3 of all test interfaces are represented as U12, U23,
U31 respectively;
6.3.3. Backlight brightness set
The default value of this item is 50, and
the backlight brightness is divided into 100 levels. It can modify any
backlight brightness by inputting the number within 1-100. Note that the
brighter the backlight, the greater the power consumption.
7、Other Instructions
& Attention
7.1. Use of Clamp
Current Sensor
7.1.1.There are 3pcs dedicated clamp current sensor of each meter, and
cannot be changed to another meter to use, and each clamp current sensor
corresponds to I1, I2, and I3 on the meter, and cannot be connected
incorrectly, otherwise it will affect test accuracy.
7.1.2.The clamp current sensor should avoid falling and impacting , the
clamp jaw must be kept clean, and the test is reliable only when the clamp jaw
completely closed.
(3) After the clamp current sensor is used,
the dust on the clamp jaw surface should be removed in time. Do not use rough
objects or corrosive agents to clean the jaw surface. It is better to use soft
cloth and lubricant (such as: WD-40 lubricant) to wipping it. It must be
cleaned before use.
7.2. Attention for
using the meter
7.2.1.This meter is only used for detection of secondary circuit and
low-voltage circuit, and cannot be used to measure the current in high-voltage
circuit to prevent electric shock.
7.2.2. When the meter use to measure three phases, the displayed phase are
all based on the A phase voltage as reference, and the displayed phases are all
relative to the absolute phase of the A phase voltage.