1.Introduction(LYBSY-3000 AC Sampling Transmitter Calibration Device)
LYBSY-3000 is the use of
modern testing, DDS waveform synthesis, high-speed digital processor (DSP),
complex programmable logic array (CPLD), large-scale integrated power
amplifier, and the design of embedded computer system technology. It is
suitable for electric energy meter (optional), AC and DC indicating instrument
test and calibration, is ideal equipment for power system the power of product
verification and calibration.
2. Main functions and features(LYBSY-3000 AC Sampling Transmitter Calibration Device)
Domestic system, measurement and signal
integration in a module, the product of high integration, low failure rate,
small volume, light weight, fast response speed, high efficiency, high
reliability, strong function, high output power, output standard source.
Is the original operating system, starting
immediately display the test picture, without guidance program, fast response
speed, high working efficiency.
The windows and buttons (with two
functions), diversity operation, suitable for different people and habits,
simple operation.
The contents of AC / DC standard source,
direct test of various DC indicating instruments.
The automatic verification energymeter
(optional) and indicator indicators.
The voltage, current, power, phase,
frequency, harmonic with superior closed-loop output, setting a place, easy to
use software to adjust.
Thevoltage, current, phase with rich common
practical, simple operation, a little place, convenient use and high
efficiency.
Equipped with digital rotary encoder
adjustment ,easy to use,simple.
The outputvoltage, current and power are
high precision, high stability standard source,
softwarecalibration.
Output standard harmonic 2~31 times, can be
single or arbitrary superposition of many harmonic output.
Between the three-phase voltage,
three-phase current, between each phase voltage and current can be arbitrary
phase shift, so it can simulate all kinds of fault output power.
Equipped with the three-phase frequency
independent phase, frequency conversion.
Equipped with multiple alarm and protection
functions, it can detect the fault automatically and show the fault type and
location. It is safe and reliable.
The preparation of interface and software,
open interface protocol, user programmable control instruments.
Can support domestic similar product
operation software.
3. Main technical index(LYBSY-3000 AC Sampling Transmitter Calibration Device)
|
AC analog output
|
|
AC voltage output
|
span
|
100V、 57.735V、 380V、 220V
|
|
Adjustment range
|
0~120%
|
|
Adjust fineness
|
0.002%
|
|
Accuracy class
|
0.05%
|
|
stability
|
0.01%/2min
|
|
Distortion
|
≤0.1%(Non-capacitive load)
|
|
Output load
|
30VA/ Channel
|
|
AC current output
|
span
|
5A、2A、1A、20A
|
|
Adjustment range
|
(0-120)%
|
|
Adjust fineness
|
0.002%RG
|
|
accuracy
|
0.05%RG
|
|
stability
|
0.01%/2min
|
|
Distortion
|
≤0.1%(Non-capacitive load)
|
|
Output load
|
25VA/ Channel
|
|
Output power
|
Active power accuracy
|
0.05%RG
|
|
Reactive power accuracy
|
0.1%RG
|
|
stability
|
0.01%/2min
|
|
Phase output
|
Adjustment range
|
0°~359.99°
|
|
Resolution
|
0.01°
|
|
accuracy
|
0.05°
|
|
Power factor
|
Adjustment range
|
-1~0~+1
|
|
Resolution
|
0.0001
|
|
accuracy
|
0.05%
|
|
frequency
|
Adjustment range
|
45Hz~65Hz
|
|
Resolution
|
0.001Hz
|
|
accuracy
|
0.002Hz
|
|
Three - phase voltage, current symmetry
and phase symmetry
|
Voltage, current symmetry
|
<0.02﹪
|
|
Phase symmetry
|
0.05°
|
|
Voltage and current harmonic output
|
harmonic order
|
2~31 times
|
|
Harmonic content
|
0~39%
|
|
Harmonic phase
|
0°~359.99°adjustable
|
|
accuracy
|
0.2%
|
|
DC output (Optional function)
|
|
DC voltage
|
Voltage range
|
75mV、10V、100V、300V、600V
|
|
Output range
|
0~120%
|
|
accuracy
|
0.05%
|
|
stability
|
0.01%/1min
|
|
Ripple content
|
≤0.5%
|
|
Adjust fineness
|
0.002%RG
|
|
Output load
|
10VA
|
|
DC current
|
Current range
|
20mA、10mA、1mA
|
|
Output range
|
0~120%
|
|
accuracy
|
0.05%
|
|
stability
|
0.01%/1min
|
|
Ripple content
|
≤0.5%
|
|
DC measurement (Optional function)
|
|
DC current measurement
|
Measuring range
|
0~20mA
|
|
accuracy
|
0.05%
|
|
DC voltage measurement
|
Measuring range
|
0~10V
|
|
accuracy
|
0.05%
|
|
Amount of electrical energy pulse
(Optional function)
|
|
Pulse output
|
Active pulse output
|
level 5V±5%,Output current 100mA
Maximum pulse frequency:5kHz
|
|
Pulse input
|
Active pulse intput
|
level 5V±5%,input current 1mA
Maximum pulse frequency:5kHz
|
|
Environmental conditions
|
|
Operating temperature
|
0℃~40℃
|
|
Relative humidity
|
≤85%
|
|
Storage conditions
|
-30℃~60℃
|
|
Other
|
|
Working power supply
|
AC220V±15%
|
|
volume
|
450×440×132mm,weight:20kg
|
4、Instrument key instructions(LYBSY-3000 AC Sampling Transmitter Calibration Device)
|
Key
|
instruction
|
|
【VRange】
|
Voltage range switching
|
|
【IRange】
|
Current range switching
|
|
【V/Y】
|
Three phase four wire and three phase three wire
Switching
Complete wiring conversion,The display status bar must have
a V or Y display.
|
|
【SET】
|
In this series, the key is undefined
|
|
【Zero】
|
All the output down to zero, and cut off
the source output, the equivalent of the source off, mainly for wire
|
|
【MENU】
|
menu
|
|
【MODE】
|
In this series, the key is undefined
|
|
【Enter】
|
enter
|
|
【XB】
|
Harmonics keys for setting harmonics.
|
|
【U】
|
Set, display, adjust the voltage
|
|
【I】
|
Set, display, adjust the current
|
|
【P】
|
Set, measure, display, adjust active
power
|
|
【Q】
|
Set, measure, display, adjust reactive
power
|
|
【Φ】
|
Set, display, adjust the phase
|
|
【F】
|
Set, display, adjust the frequency
|
|
【A】
|
Phase sequence indicator key
|
|
【B】
|
Phase sequence indicator key
|
|
【C】
|
Phase sequence indicator key
|
|
【←】
|
The cursor is shifted to the left; Dc
range selection
|
|
【→】
|
The cursor is shifted to the right; Dc
range selection
|
|
【-】
|
minus
|
|
【1】~【9】
|
number key
|
|
【 . 】
|
Decimal point
|
|
【0%】~【120%】
|
Common voltage and current test point,
press this key will also output the percentage at the same time
|
|
【0.0L】~【0.0C】
|
Commonly used capacitive, inductive load
test points
|
5、Encoder instructions(LYBSY-3000 AC Sampling Transmitter Calibration Device)
|
key
|
instruction
|
|
The encoder turns right
|
1 The number rises when the cursor is
under the digit
2 DC output range selection
|
|
The encoder turns left
|
1 The number drops when the cursor is
under the digit
2 DC output range selection
|
|
Press the encoder down
|
And the Enter key [Enter] function the
same
|
6、Wiring instructions
|
AC
voltage output
Wiring
method
|
Y
type wiring(three phase four wire)Ua Ub Uc Un
|
|
|
V
type wiring(three phase three wire) Ua Uc Un
|
|
AC
current output
Wiring
method
|
Y
type wiring(three phase four wire)Ia Ib Ic
|
|
|
V
type wiring(three phase three wire) Ia Ic (Ib Wiring short circuit)
|
|
DC
voltage output
Wiring
method
|
Connect
the Uo+ and the Rs+ to the + terminal of the test device ;
Connect
the Uo- and the Rs- to the - terminal of the test device ;
|
|
|
DC
current output
Wiring
method
|
I
+ terminal connects to the test device + terminal
I
- terminal connects to the test device - terminal
|
|
|
Dc
voltage current
Wiring
method
|
Green:
DC voltage input
Black:
DC voltage, current lowRed: DC current input
|
|
7、Instrument interface
operation instructions
7.1Menu selection interface
At any interface, press the [MENU] key
pop-up menu to select the interface:
7.2AC output interface
After power on, enter the standard output
interface, as follows:
|
|
|
|
V
|
0.000
|
0.000
|
0.000
|
DC
|
0.001
|
|
A
|
0.000
|
0.000
|
0.000
|
0.001
|
|
φU
|
0.000
|
0.000
|
0.000
|
|
|
φI
|
0.000
|
0.000
|
0.000
|
50.000Hz
|
|
W
|
0.000
|
0.000
|
0.000
|
0.000
|
|
Vr
|
0.000
|
0.000
|
0.000
|
0.000
|
|
VA
|
0.000
|
0.000
|
0.000
|
0.000
|
|
PF
|
0.000
|
0.000
|
0.000
|
0.000
|
|
|
100V 5A Type YNo harmonicOpen loop
|
AC output interface operating instructions:
|
Gear selection of voltage and current
|
press【VRange】
|
Switching voltage limit
|
|
press【IRange】
|
Switching current limit
|
|
Quick output of voltage
|
press【digit】【U】【Enter】
|
Simultaneous rise of threephase voltage
|
|
press【digit】【U】【A】【Enter】
|
rise only Ua=【digit】
|
|
press【digit】【U】【B】【Enter】
|
rise only Ub=【digit】
|
|
press【digit】【U】【C】【Enter】
|
rise only Uc=【digit】
|
|
Quick output of current
|
press【digit】【I】【Enter】
|
Simultaneousrise of threephase current
|
|
press【digit】【I】【A】【Enter】
|
rise only Ia=【digit】
|
|
press【digit】【I】【B】【Enter】
|
rise only Ib=【digit】
|
|
press【digit】【I】【C】【Enter】
|
rise only Ic=【digit】
|
|
Voltage and current angle setting
|
press【digit】【Φ】【Enter】
|
Set the threephase power factor angle =【digit】
|
|
Output frequency setting
|
press【digit】【F】【Enter】
|
Set the standard output frequency =【digit】
|
|
Coarse adjustment and finetuning of
various parameters
|
press【U】【Enter】Enter the display areaU=×××.×××
V, Rotate the digital encoder, which will adjust the digit size of the
cursor.Press 【→】 【←】 key to
move the cursor position, will realize the parameter of the coarse and fine
tuning.
|
|
press【U】【Enter】
|
Adjust the amplitude of the three-phase
voltage simultaneously
|
|
press【U】【A】【Enter】
|
Adjust the amplitude of A phase voltage
|
|
按【U】【B】【Enter】
|
Adjust the amplitude of B phase voltage
|
|
press【U】【C】【Enter】
|
Adjust the amplitude of C phase voltage
|
|
press【I】【A】【Enter】
|
Adjust the amplitude of A phase current
|
|
press【I】【B】【Enter】
|
Adjust the amplitude of B phase current
|
|
press【I】【C】【Enter】
|
Adjust the amplitude of C phase current
|
|
press【Φ】【Enter】
|
Adjust voltage and current angle
|
|
press【F】【Enter】
|
Adjust output frequency
|
|
Turn off source output
|
press【Zero】
|
Turn off source output
|
|
Three phase four wire and threephase
three wire conversion
|
press【V/Y】
|
Three phase four wire and threephase
three wire switching
|
|
switch interface
|
press【MENU】
|
Menu selection interface
|
|
|
|
|
|
7.3DC output interface
|
0.0000V
|
|
gear
|
DC voltage 600V
|
|
Gear selection
|
|
|
status
|
DC source is open, DC voltage output
|
DC output interface operating instructions
|
DC gear selection
|
Press【VRange】
|
Use the [←] [→] key to select the voltage
range
|
|
Press【IRange】
|
Use 【←】 【→】 key to
select the current range
|
|
DC voltage output
|
Press【digit】【U】【Enter】
|
output voltageU =【digit】
|
|
Press【0%】~【120%】Common voltage test point
|
The percentage voltage of the output gear
|
|
Press【U】【Enter】
|
Adjust voltage value by knob
|
|
DC current output
|
Press【digit】【I】【Enter】
|
Output current I =【digit】
|
|
Press【0%】~【120%】Common current test points
|
The percentage current of the output gear
|
|
Press【I】【Enter】
|
Adjust current value by knob
|
|
Turn off DC source
|
Press【Zero】
|
|
DC output wiring
|
DC current wiring: the connection cable
to the front panel, DC current output terminals, red terminal for the
positive,
Black terminal is negative.
|
|
DC voltage wiring: DC voltage output
using four-wire output, where UO +, UO- for the outputterminal.
|
7.4Harmonic display interface
|
Order
|
UA[%]
|
10+
|
20+
|
IA[%]
|
10+
|
20+
|
|
Total
|
0.000
|
THDU
|
0.000
|
0.000
|
THDI
|
0.000
|
|
1
|
100.00
|
0.000
|
0.000
|
100.00
|
0.000
|
0.000
|
|
2
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
3
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
4
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
5
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
6
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
7
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
8
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
9
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
10
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
0.000
|
|
A phase
|
F content
|
P add
|
Q delete
|
|
|
|
|
|
|
|
|
|
|
|
Harmonic display operation instructions
|
ABC phase switch
|
Press【A】【B】【C】
|
Switch the current display
|
|
Add \ remove harmonics
|
Press【P】【Q】
|
Enter interface
|
7.5Vector display interface
|
|
UA
|
0.00
|
|
UB
|
0.00
|
|
UC
|
0.00
|
|
IA
|
0.00
|
|
IB
|
0.00
|
|
IC
|
0.00
|
|
a
|
0.00
|
|
b
|
0.00
|
|
c
|
0.00
|
|
F customary law
|
P angle
|
Q 0~360
|
|
|
|
|
|
Vector display operation instructions
|
UA.UB.UC
|
Three phase voltage Angle
|
|
IA.IB.IC
|
Three phase current Angle
|
|
a.b.c
|
The angle between three phase voltage and
current
|
7.6electric energy calibration interface
|
Electric energy error
|
|
running
|
|
Measured electrical energy
|
|
Active power
|
|
Voltage
|
0.000
|
0.000
|
0.000
|
constant
|
0.0
|
|
Current
|
0.000
|
0.000
|
0.000
|
Number of turns
|
0
|
|
Voltage phase
|
0.000
|
0.000
|
0.000
|
Low frequency output
|
|
Current phase
|
0.000
|
0.000
|
0.000
|
50.000Hz
|
|
Active power
|
0.000
|
0.000
|
0.000
|
0.000
|
|
Reactive power
|
0.000
|
0.000
|
0.000
|
0.000
|
|
Apparent power
|
0.000
|
0.000
|
0.000
|
0.000
|
|
Power factor
|
0.000
|
0.000
|
0.000
|
0.000
|
|
State
|
100V 5A Type YNo harmonicOpen loop
|
|
|
|
|
|
|
|
|
Electric energy calibration method:
Press 【→】 key, the
cursor enters the editing state,then press the number key on the panel.Press 【→】 key, the cursor enters the next edit box,When the parameters are
all set up,press [Enter] to confirm and start the verification.
Active energy calibration and reactive
energy calibration, switching method:
Press 【→】 to the
active energy, press 【Enter】 key to
switch active or reactive.
Press 【→】 to the
constant, set the constant, press 【Enter】 to
determine.Press 【→】 to the number of turns, set the
number of turns, press 【Enter】 to
determine.
Press 【→】 to stop the
verification, press 【Enter】 to start the
calibration,
Constant setting range
set range(1A-18000;2A-9000;5A-3600;20A-900).
Number of turns setting range
set range (1---9999999)Generally set about
5 laps, refresh soon, the number of laps set bigger.
Pulse port definition

1 pin :
signal (green)
3 pin :
5V (red)
5 pin :
ground (black)
Wiring method of active electric energy
meter
Wiring method of passive electric energy meter
7.7Parameter calibration interface
This interface is
for calibration of instrument parameters. In order to ensure the accuracy of
the instrument, this interface is not open to the user.
8、Attention
The instrument must have a good grounding
in use
Check the temperature of 23 + 1 degrees.
To ensure the accuracy of the instrument,
please preheat 30 minutes before use.
Attention should be paid to the proper limits
of the objects to be measured.
instrument terminal output as standard
source, the terminal can not access any other power supply.
tandard power output, you must first select
the output voltage and phase, power loss
Out of the maximum 120% of the theoretical
value.
In this equipment and other equipment shall
disconnect all power devices connected before communication, however electrical
connections cause damage to the equipment.
When DC output 5A 25A, please raise the
current to 100%, preheat five to ten minutes.